Heat-glo-fireplace Heat & Glo Fireplace 8000TVC Manuel d'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
15
Figure 11. Fan Wiring Diagram
For Direct Spark Ignition (DSI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to
the junction box included in the manual bag assembly.
Maintain correct polarity when wiring the junction box.
The junction box is installed by sliding one tab of the box
through the slot on the lower right side of the outer wrap
and driving a screw through the other tab into the pilot
hole on the outer wrap.
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Remote Wall Switch
Position the remote wall switch in the desired position
on a wall. Run a maximum of 25 feet (7.8 m) or less of
16 A.W.G. minimum wire and connect it to the fireplace
ON/OFF switch pigtails.
NOTE
Electrical wiring must be installed by a licensed electrician.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. VERIFY PROPER OPERATION
AFTER SERVICING.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.
NOTE: IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THE APPLIANCE
MUST BE REPLACED, IT MUST BE
REPLACED WITH TYPE 105 DEGREE C
RATED WIRE.
BLOWER
BLOWER RECEPTACLE
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
TEMPERATURE
SENSOR SWITCH
GROUND
WHT
BLK
BLK
GRN
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
110-120 VAC
BLK
WHT
FAN WIRING DIAGRAM
(Located on right
side of firebox)
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 24 25