A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories.
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
13
Electrical Information
ORANGE
GREEN
GROUND
BLACK
WHITE
ORANGE
FLAME
SOLENOID
IPI
VALVE
GREEN
IPI
MODULE
LUX
CONTROL
MODULE
LEARN
BUTTON
POWER
SUPPLY
BROWN
3V DC
BROWN
BROWN
RED
BLACK
4 BLACK Wires
1
2
3
4
5
6
7
8
4 BLACK Wires
4 BLACK Wires
ORANGE
BLACK
F
M
F
M
B. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 13.1 Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.